Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Deanna from MANDAN, ND
- Parts Used:
- WR01X10450
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fridge handle missing set screw.
Opened the package. Set screw fell on floor. Luckily cat found it right away. Fight the cat for the screw. Dug through my tools and the first Allen wrench I picked up fit. "What the hell? That never happens so obviously the screw won't fit," I think to myself. Put the screw in the hole and give it a few turns until my fat finger can't hold it. It's a miracle and the thing fits! Fight the close quarters with the Allen wrench to tighten it. Works like a charm!! Now I don't scare myself when I open the door thinking I'm going to rip the handle right off. Now I have easy access to my ice cream. The parts finder tool on the website was really easy and I found what I was looking for.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jupiter, FL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dwight from phoenix, AZ
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony B from JOLIET, IL
- Parts Used:
- WR14X10237
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Old door gasket had deteriorated.
Easy repair. Old gasket removed by hand in about one minute. The new gasket was pressed in place by hand in about 3 more minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mike from Aguilar, CO
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from BELLEVUE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- Less than 15 mins
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Raymond, NE
- Parts Used:
- WR57X33326
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker making no ice
I first replaced in-line water filter to the fridge. No ice. Then I replaced the water filter inside the fridge. Still no ice. I inspected the water inlet feeding the ice cube trays and it was froze up with ice. I removed the two screws holding the ice maker in place to remove the ice from the inlet tray. I then used a hair dryer to melt the ice accumulated in the in-coming water tube. Turned off the water and unplugged the fridge. When replacing the old water valve, I first blew through the hose feeding the ice maker to be sure that it was clear of ice. After re-attaching the water hoses and the electrical connections, I turned on the water, plugged in the fridge and turned the ice maker switch back on. Next morning I had ice cubes. Only mystery is I am not hearing the usual water noise when water is feeding the cube tray like I did before, - not to worry though if it works. My drawer is now full of cubes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jose from La Vernia, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
Water dispenser would not shut off when you released it. It would spill water and run for ten or twelve seconds after removing glass and releasing dispenser.
Ordered the new part (water valve). Took off the bad one followed directions on you video. The video explained the process making it easy to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leo from TWIN FALLS, ID
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- M &M Aviation from ESCANABA, MI
- Parts Used:
- WR55X10025, WR02X10668, WR02X10647
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator side freezing food
Replaced both temp sensors worked good for 2 days then began freezing food. Looked into it further on line. Found small motorized door broken that controls the cold air from the freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Temecula, CA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water in door dispensor quit working
First, I turned off the water supply line to the refrigerator from the house at the wall and unplugged the power cord. Secondly, I removed the small screws that hold the piece of cardboard over the opening in the lower left corner (rear of the refrigerator) by the compressor. Thirdlyl, I removed the other end of the water line where it attaches to the water valve with an adjustable end wrench. Then I removed the small screw that holds the double water outlet valves to the refrigerator frame. I then removed the water valve by pulling it out of the rear of the refrigerator, unplugged the electrical connections, and cut the water lines where they enter the valves. I then plugged the electrical connectors into the new valves and pushed the hoses into their respective openings. These are one-way connectors - once you push them in (firmly) they will not leak or come back out. All I did then was replace the valve and secure it with the one little screw and then replace the cardboard piece onto the rear of the refrigerator. Don't forget to turn the water supply back on. That's it!!
Was this instruction helpful to you?
Thank you for voting!