EMO3000CBB001 General Electric Microwave - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Frank from VIPER, KY
- Parts Used:
- WB27X10928
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Blown fuse in microwave
One small Phillips screwdriver and one fuse puller (I used cord). Unplug unit. Remove the two screws on the vent face plate. Remove the one screw on the panel assembly. Gently let hang. Pull the fuse located on the upper left wall. Replace fuse. Reassemble.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shari from Sarasota, FL
- Parts Used:
- WB15X10022
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door handle broken on microwave.
Fortunately I had my handyman here to repair a leak under my kitchen sink and asked him to replace the handle on my microwave. There were no instructions included with the handle but I had printed out descriptions from the web site of what others had done. He pried off the inside of the door which revealed two screws, which he removed. He then had to pry off another covering which revealed the other two screws that removed the handle. He attached the new handle and put the two parts that were pried off back on. It would not be an easy process for the ordinary householder and it would have been nice if detailed instructions had come with the handle (with pictures showing exactly which areas of the door needed to be removed). I was going to try the repair myself but am extremely glad my handyman was there as I probably would have ruined the microwave and would have had to purchase a new one. Kudos to my handyman.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Pearland, TX
- Parts Used:
- WB36X10003, WB08X10016
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace microwave light and broken base socket
Lower base of the microwave, about 6 screws,
replaced broken light bulb socket,then re-installed.
Installed new light bulb.
replaced broken light bulb socket,then re-installed.
Installed new light bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Olive Branch, MS
- Parts Used:
- WB27X1160, WB27X10240
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
blowing 15 amp fuse when hitting power button
Looked at schematic to see which parts became active when the power button was pushed. From there used meter to determine diode was open and capacitor was shorted. Biggest trouble was dis-assembly/assembly required to get to electrical parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROGER from BLUFFTON, SC
- Parts Used:
- WB08X10016
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Loss of lighting for over-stove illumination.
Must remove 5 screws in bottom of Microwave, which is hinged to the unit. Then simply remove the old lamp holders, and replace with replacements. Uses only a single screw for each lamp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Lillian, AL
- Parts Used:
- WB27X10195
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
microwave dead
First, potatoe burned up in microwave. Microwave
was dead. Took off cover and found maintaince repair pamphlet in envelope. Schematic showed one shot thermostat for fire. Ordered thermostat from you and installed it. Works fine.
was dead. Took off cover and found maintaince repair pamphlet in envelope. Schematic showed one shot thermostat for fire. Ordered thermostat from you and installed it. Works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Mesa, AZ
- Parts Used:
- WB26X10038
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Turntable no longer went around
I followed the instructions provided by others on-line who had done a similar repair. I removed a handful of screws, disconnected the wires from the old drive motor and connected them to the new drive, replaced the screws that held the drive motor in place, and those that held the bottom housing in place, and I was done. Literally took less than 10 minutes. If I had known earlier how easy it was, the microwave would have been fixed much earlier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brenda from St. Peters, MO
- Parts Used:
- WB15X10022
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Cracked Door Handle
Removed Old Handle with minor difficulty, two screws came out easy other two had to drill out back plate to get to other two screws, after that, repair went fine.Took about an hour total time for repair, and sure saved alot of money!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cody from Omaha, NE
- Parts Used:
- WB26X10038
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Turn table stoped functioning
Troubleshooting process:
Using a screw driver I opened the bottom of the unit using a Philips screwdriver and unhooked the drive motor electrical connector. Using a multimeter I checked to ensure power to the motor. This confirmed that the motor is bad and must be replaced.
Repair process:
After receiving new motor I removed the old motor and installed the new one using a Philips screwdriver and closed up the bottom cover.
It functioned good as new. Relatively cheap and very easy fix.
Using a screw driver I opened the bottom of the unit using a Philips screwdriver and unhooked the drive motor electrical connector. Using a multimeter I checked to ensure power to the motor. This confirmed that the motor is bad and must be replaced.
Repair process:
After receiving new motor I removed the old motor and installed the new one using a Philips screwdriver and closed up the bottom cover.
It functioned good as new. Relatively cheap and very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Muskego, WI
- Parts Used:
- WB26X10038
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Cooking tray drive motor did not work.
Unpugged microwave. Removed the screws on the bottom cover of the micorwave. Unpugged drive motor and removed two screws from drive motor. Installed new motor and replaced the bottom cover, plugged in microwave . . . presto!
Installation was just as easy as numerous other customers indicated. Also, your service was as great as many other customers indicted . . . part was recieved in 2 business days. Thank you for great service and website.
Installation was just as easy as numerous other customers indicated. Also, your service was as great as many other customers indicted . . . part was recieved in 2 business days. Thank you for great service and website.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lawrence from huntersville, NC
- Parts Used:
- WB08X10016
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Bulb was stuck in the lamp
First I removed the screws that were underneath the microwave. Once I did that I disconnected the wires to the bulbs and removed the screws that were attached to the holder lamp. replaced the parts and reversed the process. It went really smooth.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Cleveland, OH
- Parts Used:
- WB36X10003
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
under microwave (above stove) light
The replacement of the light no problem, the reason the light broke; problem. The original was glued in (for transport i think) and simply trying to unscrew it out (in a very tight slot) it broke; be careful or you’ll be buying a new $20 bulb (with shipping and handling).
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Fort Smith, AR
- Parts Used:
- WB36X10003
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Bulb burned ot
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from stamford, CT
- Parts Used:
- WB15X10022
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
door handle broke ge nolonger stocked door or handle
took a screw driver and pride off plastic on inside of door. be carfule not to break it. only one of two screws that go into handle were visable. had to drill a hole in metal braket to get at second screw. you can just bend the metal braket back inorder to use drill. bend it back when done. took off handle and replaced it. snapped plastic piece I took off back in place and finished.
ge told me i needed to replace whole door. which they nolonger stock and I could not find a whole door for my model on web. found handlw on this website and did it my self
ge told me i needed to replace whole door. which they nolonger stock and I could not find a whole door for my model on web. found handlw on this website and did it my self
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Bakersfield, CA
- Parts Used:
- WB06X10138
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Sparked at the coupler, burnt
Using the exploded parts view I removed three Philips screws from the lower plate (the screws are located on the front edge of the panel that holds the air filters). Slide the lower panel forward slightly and allow it to swing down. Remove the amphenol connector to the motor and hood lights by pressing the sides of the plastic clip and place the lower panel to one side out of the way. f you intend to clean the lower panel in a dishwasher remove all electrical components before doing so (bend back the clips holding the wires in place and remove the lamps, remove the Philips screws holding the lamp holders); note: these are the only screws with a short shoulder on them, make sure they go back in the same place to hold the lamp holder to prevent damage to the holder). Remove the Philips screw holding the turn table motor in place. Slide the entire motor assembly to one side to allow the motor shaft to slide off the coupler. With the oven door open, remove the old coupling by sliding it to one side to clear the retainer. Insert the new coupling and replace the motor making sure you align the motor shaft with the flat side of the coupling. If you have cleaned the lower assembly in the dishwasher or by hand make sure all parts are dry before reassembly (reinstall the lamp holders and the wiring assembly. Reconnect the amphenol connector (it can only plug in one way by nature of design). Slide the back of the lower assembly into the channel at the back of the oven and replace the three screws holding the lower panel in place.
Now you have saved your self the cost of a service call or possibly a new microwave you can use this as supporting evidence that you can afford the new 20" monitor for your PC. Test out the repair and make your spouse a cup of hot coffee or cocoa to brag on yourself and make your sales pitch.
Now you have saved your self the cost of a service call or possibly a new microwave you can use this as supporting evidence that you can afford the new 20" monitor for your PC. Test out the repair and make your spouse a cup of hot coffee or cocoa to brag on yourself and make your sales pitch.
Was this instruction helpful to you?
Thank you for voting!