Neil from Williston, VT
Parts Used:
WB20X10048
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Lack of power to unit
This is the second time replacing this fuse, last time was exactly one year ago. The first time I replaced it, I removed the oven from the wall & disassembled a number of things to reach the culprit. This time I left the oven mounted & was able to access the 2 grille mounting screws on the top of the grille & remove it. Next comes the black plastic air deflector held by two screws & is mounted in front & on the right, it is shown on the parts list just above part #1434. After removing it, remove the two silver cover screws in the front, this cover also doesn't have a part # but is shown to the right of part #1410. At this point you can lift this cover enough to access the fuse which is on the left & held in place by one tiny screw through the clamp at the top, (careful not to drop it when removing). PS: Don't forget to cut the power to the microwave before starting!
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Brookfield, CT
Parts Used:
WB20X10048
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
after 3-4 minutes microwave display would blink and unit would just cut out.
This was the second time I've had to open up the microwave. 1st time display would blank out but system would continue to operate. Found solder connections on board to LED display were defective. Resoldered and unit was fine. This time I found the connection to the oven cavity temp cut-off was bad, plastic connection cover melted. When unit operated bottom lead and wire would heat up. Couldn't measure a Discernable distance so either wire or connector connection surface was not sufficient to carry the current. 1st replaced sensor still wire heated up. Replaced connector and there was no sign how heat from resistances.
12 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aaron from BLUE RIDGE, TX
Parts Used:
WB26X32629
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave function not working
1) Removed 4 screws securing the microwave to the cabinet.2) Slid microwave out, unplugged and placed on a work surface that allowed lower trim to hang over. 3a) Removed two screws and removed the cover on top of the oven. 3b) Unplugged high voltage plug from Magnatron. 4) Removed wires from overtemp fuse mounted to Magnatron. 5) Removed the four screws securing the Magnatron to the oven. 6) Removed Manatron. It's a tight fit, but can be done without removing anything else. 7) Replaced Magnatron. This is where I needed the magnetic part retrieval tool. The nature of a Magnatron is the use of strong magnets surrounding the tube. Getting the four screws back into place wasn't possible with just a normal magnetic screwdriver tip. I used the retrieval tool to position the screws back in place. Be sure to not initially tighten any screw completely, until they can be evenly tightened. This ensures correct compression/seating of the shielding material near the neck of the tube. 8) Reverse removal steps. Plugged in and tested microwave function on a cup of tap water. 9) Reinstated in cabinet and got a big thank you kiss from the wife!
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from VIPER, KY
Parts Used:
WB27X10928
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Blown fuse in microwave
One small Phillips screwdriver and one fuse puller (I used cord). Unplug unit. Remove the two screws on the vent face plate. Remove the one screw on the panel assembly. Gently let hang. Pull the fuse located on the upper left wall. Replace fuse. Reassemble.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronie from BRIARWOOD, NY
Parts Used:
WB27X10928
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Microwave does not have power at all, though outlet has power
unplugged power cable / unhooked front vent / unscrew the monitor panel / slide up to dislodge / take the fuse out and put in the new one in / fuse is located right in front of monitor panel once its open might be covered by wirings / you can unpin the cables from the panel to make it easier for you just make sure to put it back properly or you can have somebody hold the panel for you. Installing the fuse is easy waiting for the parts is crazy......
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Seven from MOUNT AIRY, MD
Parts Used:
WB27X35382
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave not heating.
Followed the instructions on your website and a YouTube video. The diode was at a 90 degree angle which made it a little trickier. Unfortunately the repair did not resolve the problem. I ended up buying a new microwave for temporary use for less than ordering any more parts. We are pleased with your website, instructions, ease of installation though!
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Erie, PA
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
microwave would not heat
First remove all screws holding on outer metal casing of microwave. Next remove the back and bottom metal pieces. You will then be able to pull aside the outer casing so you can access the door switches. Check each switch with an ohm meter in both the open position and with the switch closed. If the ohm meter reads the same in both the open and closed position, the switch is bad. Check the top switch first. Replace switch and reassemble. Cheap fix for a costly microwave. Great customer service at Parts Select!
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Springfield, VA
Parts Used:
WB27X10857
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Oven wouldn't sensor reheat & error code on display
I looked at the exploded pic on your web site to find the location of the sensor. Next I removed the cover by unscrewing 15 screws then swaped the sensor and re assembled! Works great! Fixing it my self I saved at least 150$ and did not have to wait all day for a repair man who probaly would not have the part on the first visit.
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Reid from LITTLETON, CO
Parts Used:
WB26X32629
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Sparking from the magnetron
Symptom: Terrible sparking coming from the right side of the microwave even with nothing in the microwave. The part that was behind the cover was the business end of what I learned was the magnetron,

Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.

I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Woody from MOSES LAKE, WA
Parts Used:
WB26X32629, WB27X35382, WB27X10928
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
No heat.
Microwave with no heat. Removed casing and checked low voltage side from the fuse through all the microswitches to the primary side of the transformer, all good. Checked HV diode good. Checked secondary side of transformer, good. Checked capacitor, good. Even though the Magnatron electrically checked out good, it had a cracked magnet. Replaced the magnatron and we have heat again!
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharry from Lititz, PA
Parts Used:
WB02X35488
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Microwave bulb was burnt out
It is easy to repair the burnt out bulb if one has the correct bulb. Your website is very user friendly and your service is great. I was not able to replace the bulb at this time because our RV is at the repair shop for some other matters. I am sure the installation of the new bulb will go smoothly. Thanks for asking. Sharry Kiehl
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry Totten from GROVES, TX
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill.
My micro is only 2 years old so I was hoping it wasn't anything major.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from PIEDMONT, CA
Parts Used:
WB26X32629
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
runs but does not heat
I removed the main cover ( torx security bit required) and tested the magnetron, capacitor, diode and door interlock switches according to instructions found on the internet. The capacitor and diode tested good but the magnetron looked burnt and corroded on the tip. The magnetron I received was an exact replacement for the original. It was easy to replace the magnetron which arrived in 2 days standard shipping. I also cleaned the fan while I had access to the inside area. Hoping to get another 18 years use from the microwave!
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daryl from Salado, TX
Parts Used:
WB27X35382, WB27X10928
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Wrench (Adjustable)
MICROWAVE WAS NOT HEATING THE FOOD
So my microwave was turning on and operating but nothing would get hot or even Luke warm. After watching several online videos on the problem I replaced the line fuse, diode, and the magnetron. I figured why waste time and just do all 3 while I have the thing apart. I discharged the capacitor with a light bulb first before doing anything. Also had to pop the safety pins on the outside screws to take the metal housing off the microwave. Then Wallah! Everything is working and the food or liquid is hotter than it ever was. The only think that bothers me a little bit is that after the microwave shuts off, I can hear a few crackles or faint pops for about 5 seconds. I wonder if this is anything to worry about. Comments appreciated.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Bessemer, MI
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
mICROWAVE WOULD NOT HEAT
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!